Skip to main content

BiliCheck vs JM-103 in identifying neonates not at risk of hyperbilirubinaemia

Abstract

Background

Transcutaneous bilirubinometry is widely used to predict hyperbilirubinemia by using several devices. The aim of this study was to compare the predictive ability of BiliCheck vs JM-103 in identifying neonates not at risk of significant hyperbilirubinemia, putting the data obtained with the two instruments on our transcutaneous bilirubin nomogram built with the BiliCheck.

Methods

Transcutaneous bilirubin (TcB) measurement was performed when jaundice appeared in newborn babies and/or just before discharge from the hospital. It was performed at the forehead with the two instruments within 5 minutes by two experienced neonatologists, each one blind to the value obtained by the other. Blood samples were drawn to obtain total serum bilirubin (TSB) levels soon after TcB measurements.

Results

A total of 627 paired-sample measurements were obtained from 298 newborn babies. Out of the total population studied, 16 newborn babies (5.4%) showed significant hyperbilirubinemia defined as TSB value >17 mg/dL, or as need for phototherapy treatment according to the AAP guidelines. TcB measurements showed false negative results in the first 60 hours of life using both devices. After the 60th hour of life, TcB measurements using both devices successfully predicted newborn babies not at risk of significant hyperbilirubinemia, being the JM-103 more reliable than BC because of fewer false positive results.

Conclusions

Our study shows that both BC and JM-103 can exclude subsequent significant hyperbilirubinemia when the measurements are performed after the 60th hour of life. Nevertheless, the transcutaneous pre-discharge screening should be considered only as the first step, and it has to be followed by a follow-up through the first days after discharge.

Background

Early discharge of healthy late preterm and full term neonates from hospital influenced an increase in hospital readmission rates due to hyperbilirubinemia, and even the more serious reappearance of kernicterus [1, 2]. Visual assessment of jaundice and risk factors evaluation did not give positive results in predicting subsequent hyperbilirubinemia [3, 4], while plotting total serum bilirubin (TSB) measurements on hour-specific nomograms allowed the reduction in hospital readmission rate for severe hyperbilirubinemia (TSB > 30 mg/dl) [58]. The suitability of transcutaneous determination of bilirubin (TcB) to reduce both the need and adverse effects of TSB measurement has been widely documented [915]. Several hour-specific nomograms for TcB have been developed [14, 1620] but few of them have been prospectively validated [21, 22]. In the past years we developed a skin bilirubin nomogram for the first 96 h of life in a European normal healthy population using BiliCheck™([BC] Respironics, Marietta, GA – USA) and then validated it in a prospective, observational multicenter study [18, 22]. BC and JM-103 (Drager Medical Inc, Telford, Pennsylvania) reliability has been evaluated in two recently published papers [23, 24]. The purpose of this study was to compare the predictive ability of BiliCheck vs JM-103 in identifying neonates not at risk of significant hyperbilirubinemia, putting the data obtained with the two instruments on our transcutaneous bilirubin nomogram built with the BiliCheck.

Methods

Study population

This prospective cohort study was conducted through January to July 2011 in a single maternity ward.Ethics committee of the Department of Paeditrics approved the study and the consent form. Informed consent was obtained from both parents. The inclusion criteria were gestational age ≥35 weeks (based on ultrasound assessment in the first trimester, if available or on postmenstrual age otherwise), absence of congenital malformation and of any disease requiring an admission to the neonatal intensive care unit. Intramuscular administration of 1 mg vitamin K was the only drug administered to studied infants. Breast or bottle feeding every 3 hours was started within one hour of life.

Measurement of TcB and TSB

The measurement of TcB was performed on each baby either when he/she was visually jaundiced and/or just before discharge from the hospital. The determination of TcB was made at the forehead with the two instruments within 5 minutes, according to manufacturer instructions. BC was calibrated before each measurement using a BiliCal™, and each measurement was performed with 5 readings in different points of neonatal forehead. JM- 103 was used on the forehead performing 5 readings too. Reading locations for both devices were distanced from the hairline and free of any bruising, nevus, haemangioma or other skin anomalies. Each device was used by one neonatologist unaware of the other one’s results and of the TSB level. A blood sample (50 μl) for TSB measurement was obtained by heel stick puncture, soon after TcB measurement. Capillary tubes were protected from ambient light and were assayed with direct spectrophotometer (Microbilimeter Dual Beam Plus model, Ginevri, Rome, Italy) after centrifugation. A total of 627 paired-sample measurements were obtained from 298 newborn babies.

Follow-up of studied infants

Newborn babies were never discharged before 72 h of age, independently from the mode of delivery. All newborn babies with a pre-discharge TSB value > 75th percentile of our nomogram were discharged only after two consecutive decreasing TSB values, 12 hours apart, making us able to identify the peak TSB level. Newborn infants with pre-discharge TSB level between the 50th and the 75th percentile were discharged and controlled 48 h later for hyperbilirubinemia using TSB measurement. Parents of infants with TSB <50th percentile were counseled to return to the hospital within 5 days, or earlier if they observed a persistent jaundice. The decision to use phototherapy was made by the attending neonatologist according to AAP guidelines [25]. For babies exposed to phototherapy we considered only pre-treatment measurements. All perinatal data were recorded in a single database with a selected log of any event occurring during the study period.

Outcome

Measurements of TcB were plotted on our percentile-based hour-specific nomogram separately by two researchers after completion of the study. Significant hyperbilirubinemia was defined as TSB value >17 mg/dL, or as need for phototherapy treatment according to the AAP guidelines. Newborn babies with TcB value below the 75th percentile that developed subsequent significant hyperbilirubinemia were defined as false negative results.

Statistical analysis

In our previous experience, BC showed to be 96% sensitive using the 75th percentile of our nomogram [22]. Sample size and power analysis were calculated assuming that JM-103 would be at least 90% sensitive to be considered equivalent. Calculations derived a sample size of 564 paired measurements to yield 80% power with alfa 0.05.

We used the Student’s t-test for continuous predictors and the Fisher’s test for categorical data. We calculated the sensitivity, specificity, positive predictive and negative values plotting TcB data against the 75th percentile of our TcB nomogram because this percentile resulted the best predictor in a previous multicenter study performed on our population. Receiver operating characteristic (ROC) curve analysis was performed with SPSS software, which was used to assess the predictive ability of the two studied devices. ROC curves were compared using the Hanley & McNeil method.

Results

A total of 298 newborn babies (143 males and 155 females, 279 full term and 19 late preterm) were enrolled in the study (Table 1). Mean gestational age (±SD) was 38.7 (1.4) weeks (range: 35–42) and mean birth weight (BW) was 3200 (440) g (range: 1830–4430). The majority of babies were Caucasian (92.3%) and were born after spontaneous delivery (58.4%). Breast and/or bottle feeding were the prevalent feeding methods, only 34.9% received exclusive breastfeeding. Delayed meconium passage (>24 h of life) was observed in 20 (6.7%) babies, and only 12 (4.0%) had a weight loss greater than 10%. Out of the total studied population, 16 newborn babies (5.4%) were diagnosed as having significant hyperbilirubinemia, and 9 (3.0%) received phototherapy. None of the babies required an exchange transfusion. No cases of significant hyperbilirubinemia were noticed among not jaundiced babies. The mean variation coefficient for BC and JM-103 was 7.4% ± 1% and 6.9% ± 1.2%, respectively.

Table 1 Baseline characteristics of the study population

Table 2 shows the predictive ability of the 75th percentile of our TcB nomogram to identify babies with significant hyperbilirubinemia using the TcB measurements obtained by BC and JM-103. TcB measurements using both the devices showed false negative results in the first 60 hours of life. In this period, BC values were more reliable than JM-103 values because of less false negatives, but with more false positives. After the 60th hour of life there were no false negative results for both the devices, but JM-103 was more reliable because of less false positive results.

Table 2 Ability of JM-103 and BC measurements below the 75th percentile of TcB nomogram (ref.[22]) to predict significant hyperbilirubinemia, for designated time periods

The ROC curve for the 75th percentile of TcB is shown in Figure 1 where the true positive rate (sensitivity) was plotted in function of the false positive rate (1-specificity). The area under the ROC curve (AUC) measured the accuracy of the percentiles in predicting significant hyperbilirubinemia using JM-103 or BC. AUCs for both the devices were lower in the first 24–60 hours of life than between 61–96 hours. JM-103 had higher AUC than BC between 61–96 hours, and this difference borders statistical significance (p = 0.074).

Figure 1
figure 1

ROC curves during different hours of age: A) 24–60 h; B) 61–96. Full line and dashed line represent the BC and the JM-103 performance, respectively.

In order to calculate the execution times of both procedures for a subset of 50 newborn babies, a second investigator clocked times for TcB measurements. Mean time for one TcB measurement was 41.2 (5.0) sec (range: 38–55 sec) for BC and 19.2 (2.6) sec (range: 16–25 sec) for JM-103. The longer time for BC was mainly due to the calibration procedure.

Discussion

Even if healthy term newborns are discharged in many countries before the 60th hour of life, this burdening problem is not yet clearly defined [26]. The Expert Committee for Severe Neonatal Hyperbilirubinemia and European Society for Pediatric Research and American Academy of Pediatrics published detailed recommendations emphasizing the importance of universal, systematic assessment of the risk of severe hyperbilirubinemia, suggesting that a systems-based approach to prevent severe neonatal hyperbilirubinemia should be implemented at all birthing facilities and coordinated with continuing ambulatory care [27]. Therefore, the identification of newborn babies at risk of severe hyperbilirubinemia is still one of the most challenging problems for the neonatologist. The use of TSB measurement before discharge from the hospital reduced the number of babies with very high levels of bilirubin [58], but apparently it did not reduce the incidence of bilirubin-induced neurological damage [28]. TcB use to avoid TSB measurement, reducing the pain and risks of this procedure, progressively increased during the last years [915]. We recently validated our TcB nomogram in a large Italian prospective study, showing that 100% of sensitivity can be obtained with TcB measurements only after 48 hours of life, using the 75th percentile [22]. However, two recent papers from South Carolina and Canada raised some concerns because of false-negative results from pre-discharge TcB screening [29, 30]. Moreover, it is not known if the hour specific TcB nomogram developed with measurements obtained with the BC could have the same predictivity when a different transcutaneous bilirubinometer is used. The present study was performed for this reason, in order to compare the predictive ability of BC vs JM-103 using our transcutaneous bilirubin nomogram built with the BC.

Our experience showed that 100% sensitivity was obtained after 60 hours of life for both devices, giving JM-103 less false positive results. In the first 60 hours of life there were false negative results with both devices (2 with BC and 3 with JM-103) but JM-103 had less false positive results. Furthermore, JM-103 was less time consuming and less expensive because of the absence of consuming materials.

Our data ask for caution when TcB measurements and TcB nomogram are used as predictive tools if an early (<60 hours) discharge from the hospital is performed. While our previous experience with BC showed the best predictive power after 48 hours of life, in this present work we had one false negative with both the devices between 48 and 60 hours of life. These false negative results would have not been identified even if the risk factors for hyperbilirubinemia suggested by Keren et al. and by Maisels et al. were applied [3, 21]. In fact, both the infants were white, males, spontaneously delivered at 36 and 37 weeks of gestation, and had a normal clinical course in the first 72 hours of life. They were breast and bottle fed and had a normal weight loss (<7%). They were discharged at 72 hours of life and were controlled 48 hours later reaching their maximum bilirubin level (17.2 mg/dL) at 85 and 98 hours of life.

This study has some limitations: it is not a population-based study because the enrolment was based on clinical practice, it includes a vast majority of Caucasian newborn babies, and the incidence of significant hyperbilirubinemia is low. Their strengths are its robust design and the high follow-up rate for enrolled newborn babies. All babies referred to our ambulatory care facility for clinical evaluation after discharge, and no case of readmission for hyperbilirubinemia was noticed.

Conclusions

Our study shows that BC and JM-103 can be used for the TcB measurements to exclude significant hyperbilirubinemia after the 60th hour of life. Nevertheless, our experience suggests that the pre-discharge screening for hyperbilirubinemia should be considered only as the first step of a long route that ends only after an accurate follow-up through the first days after discharge. Therefore, we agree with Fay et al. [26] when they state that the follow-up for hyperbilirubinemia should not be discouraged by risk screening practice, without exposing newborn babies to unnecessary and unjustified risks.

References

  1. Maisels MJ, Kring E: Length of stay, jaundice, and hospital readmission. Pediatrics. 1998, 101: 995-998. 10.1542/peds.101.6.995.

    Article  CAS  PubMed  Google Scholar 

  2. Ip S, Lau J, Chung M, Kulig J, Sege R, Glicken S, O’Brien R: Hyperbilirubinemia and kernicterus: 50 years later. Pediatrics. 2004, 114: 263-264. 10.1542/peds.114.1.263.

    Article  PubMed  Google Scholar 

  3. Keren R, Luan X, Friedman S, Saddlemire S, Cnaan A, Bhutani VK: A comparison of alternative risk assessment strategies for predicting significant neonatal hyperbilirubinaemia in term and near-term infants. Pediatrics. 2008, 121: e170-e179. 10.1542/peds.2006-3499.

    Article  PubMed  Google Scholar 

  4. Riskin A, Tamir A, Kugelman A, Hemo M, Bader D: Is Visual Assessment of jaundice reliable as a screening tool to detect significant neonatal hyperbilirubinemia?. J Pediatr. 2008, 152: 782-787. 10.1016/j.jpeds.2007.11.003.

    Article  CAS  PubMed  Google Scholar 

  5. Bhutani VK, Johnson L, Sivieri EM: Predictive ability of a predischarge hour specific serum bilirubin for subsequent significant hyperbilirubinemia in healthy term and near-term newborns. Pediatrics. 1999, 103: 6-14. 10.1542/peds.103.1.6.

    Article  CAS  PubMed  Google Scholar 

  6. Burke BL, Robbins JM, Bird M, Hobbs CA, Nesmith C, Tilford JM: Trends in hospitalizations for neonatal jaundice and kernicterus in the United States, 1988–2005. Pediatrics. 2009, 123: 524-532. 10.1542/peds.2007-2915.

    Article  PubMed  Google Scholar 

  7. Eggert LD, Wiedmeier SE, Wilson J, Christensen RD: The effect of instituting a prehospital-discharge newborn bilirubin screening program in an 18-hospital health system. Pediatrics. 2006, 117: e855-e862. 10.1542/peds.2005-1338.

    Article  PubMed  Google Scholar 

  8. Mah MP, Clark SL, Akhigbe E, Englebright J, Frye DK, Meyers JA, Perlin JB, Rodriguez M, Shepard A: Reduction of significant hyperbilirubinemia after institution of predischarge bilirubinscreening. Pediatrics. 2010, 125: e1143-e1148. 10.1542/peds.2009-1412.

    Article  PubMed  Google Scholar 

  9. Maisels MJ, Kring E: Transcutaneous bilirubinometry decreases the need for serum bilirubin measurements and saves money. Pediatrics. 1997, 99: 599-601. 10.1542/peds.99.4.599.

    Article  CAS  PubMed  Google Scholar 

  10. Mishra S, Chawla D, Agarwal R, Deorari AK, Paul VK, Bhutani VK: Transcutaneous bilirubinometry reduces the need for blood sampling in neonates with visible jaundice. Acta Paediatr. 2009, 98: 1916-1919. 10.1111/j.1651-2227.2009.01505.x.

    Article  CAS  PubMed  Google Scholar 

  11. Carceller-Blanchard A, Cousineau J, Delvin EE: Point of care testing: Transcutaneous bilirubinometry in neonates. Clin Biochem. 2009, 42: 143-149. 10.1016/j.clinbiochem.2008.09.106.

    Article  CAS  PubMed  Google Scholar 

  12. Karon BS, Teske A, Santrach PJ, Cook WJ: Evaluation of the BiliChek noninvasive bilirubin analyzer for prediction of serum bilirubin and risk of hyperbilirubinemia. Am J Clin Pathol. 2008, 130: 976-982. 10.1309/AJCPRX1E3NWCXHMZ.

    Article  PubMed  Google Scholar 

  13. Ahmed M, Mostafa S, Fisher G, Reynolds TM: Comparison between transcutaneous bilirubinometry and total serum bilirubin measurements in preterm infants <35 weeks gestation. Ann Clin Biochem. 2010, 47: 72-77. 10.1258/acb.2009.009072.

    Article  CAS  PubMed  Google Scholar 

  14. Engle WD, Jackson GL, Sendelbach D, Manning D, Frawley WH: Assessment of a transcutaneous device in the evaluation of neonatal hyperbilirubinemia in a primarily Hispanic population. Pediatrics. 2002, 110: 61-67. 10.1542/peds.110.1.61.

    Article  PubMed  Google Scholar 

  15. De Luca D, Zuppa AA, Cota F, Zecca E, Romagnoli C: Multiwavelenght transcutaneous bilirubinometry: suitability and cost analysis. Ital J Pediatr. 2006, 32: 328-329.

    Google Scholar 

  16. Sanpavat S, Nuchprayoon I, Smathakanee C, Hansuebsai R: Nomogram for prediction of the risk of neonatal hyperbilirubinemia, using transcutaneous bilirubin. J Med Assoc Thai. 2005, 88: 1187-1193.

    PubMed  Google Scholar 

  17. Maisels MJ, Kring E: Transcutaneous bilirubin levels in the first 96 hours in a normal newborn population of ≥35 weeks’ gestation. Pediatrics. 2006, 117: 1169-1173. 10.1542/peds.2005-0744.

    Article  PubMed  Google Scholar 

  18. De Luca D, Romagnoli C, Tiberi E, Zuppa AA, Zecca E: Skin bilirubin nomogram for the first 96 h of life in a European normal healthy newborn population, obtained with multiwavelength transcutaneous bilirubinometry. Acta Paediatr. 2008, 97: 146-150. 10.1111/j.1651-2227.2007.00622.x.

    Article  CAS  PubMed  Google Scholar 

  19. Fouzas S, Mantagou L, Skylogianni E, Mantagos S, Varvarigou A: Transcutaneous bilirubin levels for the first 120 postnatal hours in healthy neonates. Pediatrics. 2010, 125: e52-e57. 10.1542/peds.2009-0403.

    Article  PubMed  Google Scholar 

  20. Yu Z-B, Dong X-Y, Han S-P, Chen Y-L, Qiu Y-F, Sha L, Sun Q, Guo XR: Transcutaneous bilirubin nomogram for predicting neonatal hyperbilirubinemia in healthy term and late preterm Chinese infants. Eur J Pediatr. 2011, 170: 185-191. 10.1007/s00431-010-1281-9.

    Article  CAS  PubMed  Google Scholar 

  21. Maisels MJ, DeRidder JM, Kring EA, Balasubramaniam M: Routine transcutaneous bilirubin measurements combined with clinical risk factors improve the prediction of subsequent hyperbilirubinaemia. J Perinatol. 2009, 29: 612-617. 10.1038/jp.2009.43.

    Article  CAS  PubMed  Google Scholar 

  22. Romagnoli C, Tiberi E, Barone G, De Curtis M, Regoli D, Paolillo P, Picone S, Anania S, Finocchi M, Cardiello V, Zecca E: Validation of transcutaneous bilirubin nomogram in identifying neonates not at risk of hyperbilirubinaemia: A prospective, observational, multicenter study. Early Hum Dev. 2012, 88: 51-55. 10.1016/j.earlhumdev.2011.07.001.

    Article  PubMed  Google Scholar 

  23. Romagnoli C, Zecca E, Catenazzi P, Barone G, Zuppa AA: Transcutaneous bilirubin measurement: comparison of Respironics BiliCheck and JM-103 in a normal newborn population. Clin Biochem. 2012, 45 (9): 659-662. 10.1016/j.clinbiochem.2012.03.014.

    Article  CAS  PubMed  Google Scholar 

  24. Raimondi F, Lama S, Landolfo F, Sellitto M, Borrelli AC, Maffucci R, Milite P, Capasso L: Measuring transcutaneous bilirubin: a comparative analysis of three devices on a multiracial population. BMC Pediatr. 2012, 12: 70-10.1186/1471-2431-12-70.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  25. AAP Subcommittee on Hyperbilirubinaemia: Management of hyperbilirubinaemia in the newborn infant 35 or more weeks of gestation. Pediatrics. 2004, 114: 297-316.

    Article  Google Scholar 

  26. Catz C, Hanson JW, Simpson L, Yaffe SJ: Summary of workshop: early discharge and neonatal hyperbilirubinemia. Pediatrics. 1995, 96: 743-745.

    CAS  PubMed  Google Scholar 

  27. Bhutani VK, Maisels MJ, Stark AR, Buonocore G: Expert Committee for Severe Neonatal Hyperbilirubinemia; European Society for Pediatric Research; American Academy of Pediatrics Management of jaundice and prevention of severe neonatal hyperbilirubinemia in infants > or = 35 weeks gestation. Neonatology. 2008, 94 (1): 63-67. 10.1159/000113463.

    Article  PubMed  Google Scholar 

  28. Fay DL, Schellhase KG, Suresh GK: Bilirubin screening for normal newborns: a critique of the hour-specific bilirubin nomogram. Pediatrics. 2009, 124: 1203-1205. 10.1542/peds.2009-0190.

    Article  PubMed  Google Scholar 

  29. Slaughter J, Annibale D, Suresh G: False-negative results of pre-discharge neonatal bilirubin screening to predict significant hyperbilirubinemia: a need for caution. Eur J Pediatr. 2009, 168: 1461-1466. 10.1007/s00431-009-0950-z.

    Article  CAS  PubMed  Google Scholar 

  30. Rodriguez-Capote K, Kim K, Paes B, Turner D, Grey V: Clinical implication of the difference between transcutaneous bilirubinometry and total serum bilirubin for the classification of newborns at risk of hyperbilirubinaemia. Clin Biochem. 2009, 42: 176-179. 10.1016/j.clinbiochem.2008.09.108.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Costantino Romagnoli.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

CR and EZ designed the study and have made substantial contributions in drafting manuscript. PC, LG, and RR performed data acquisition and validation. GB and PC contributed to interpretation of data and performed statistical analysis. AAZ verified data analysis and revised the manuscript critically. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Authors’ original file for figure 2

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Romagnoli, C., Catenazzi, P., Barone, G. et al. BiliCheck vs JM-103 in identifying neonates not at risk of hyperbilirubinaemia. Ital J Pediatr 39, 46 (2013). https://doi.org/10.1186/1824-7288-39-46

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1824-7288-39-46

Keywords